Technical Specifications
-
Metering Pump Effective Area.: 0.124 – 1.49 in2 (80 – 960 mm2) per side
-
Small Air Cylinder Effective Area: 7.07 in2 (4560 mm2)
-
Large Air Cylinder Effective Area: 15.9 in2 (10260 mm2)
-
Maximum Stroke Length : 1.50 in (38.1 mm)
-
Minimum Stroke Length: 0.23 in (5.8 mm)
-
Volume per Cycle: 0.12 – 4.3 in3 (2 – 70 cc)
-
Pump Cycles per 1L (.26 gal): 500 – 14.3
-
Ratios (variable): 1:1 to 24:1 depending on cylinders selected
-
Maximum Fluid Working Pressure: 3000 psi (207 bar, 20.7 MPa)
-
Maximum Air Input Pressure: 100 psi (7 bar, 0.7 MPa)
-
Maximum Cycle Rate: 30 cpm
-
Maximum Operating Temperature :
-
70° C (160° F) nylon pistons
-
50° C (120° F) UHMWPE pistons or PE tanks
-
Air Inlet Size: 1/4 NPT(f)
-
Wetted Parts: 303/304, 17-4 PH, hard chrome, Chromex™, carbide, chemical resistant O-rings, PTFE, nylon, UHMWPE
-
Weight – PR70v: 160 lb (73 kg) typical with two 7.5 l tank, 370 lb (168 kg) typical with two 60 l tanks
-
Compressed Air: < 10 scfm typical (varies with cycle time)
-
Electrical Power: 100-240V 50/60Hz 1 phase for machine – 80 watt
-
208–240V 50/60Hz 1 phase for heat – 10 kW max
-
120 or 240V 50/60Hz 1 phase for on-board agitators
*PR70 machines and complete configured packages carry the CE mark.